Occupancy Load Calculator

Pick the function of each space and enter its floor area and get the occupant load from IBC 2021 Table 1004.5, space by space and in total.

Workplace & SafetyUnited States onlySource: 2021 IBC Section 1004.5 and Table 1004.5Free, no sign-up

Net area: exclude walls, corridors, toilets, closets.

Gross area: inside the exterior walls.

Spaces without fixed seating. The result updates as you type.

Occupant load (IBC Table 1004.5)

82 occupants

2 spaces; each rounded up to whole people

FunctionAreaFactorOccupantsMax if increase approved (1 per 7 ft²)
Assembly without fixed seats — unconcentrated (tables and chairs)1,200 ft²15 net80 (80)171
Kitchens, commercial400 ft²200 gross2 (2)57

What this page cannot tell you

What your building official will accept. The official decides the function of a space, gross vs net areas, any approved increase, and how egress, exits and plumbing follow from the load. Fixed seating, malls and local amendments use other rules. This is for planning only.

Method: floor area ÷ occupant load factor (ft² per occupant), rounded up — 2021 IBC §1004.5 and Table 1004.5; §1004.5.1 caps an approved increase at one occupant per 7 ft². Read on codes.iccsafe.org 2026-10-17.

How to calculate occupant load

  1. Split the building into spaces. One entry per function: dining, kitchen, offices, storage.
  2. Pick each function. From IBC Table 1004.5; each has a factor in square feet per occupant, gross or net.
  3. Enter each area. Gross or net, as the factor says.
  4. Read the load. Occupants per space, rounded up, and the total.

10 situations where an occupancy load calculator helps

Opening a restaurant

Dining with tables and chairs is 15 ft² net per person; the kitchen 200 gross.

Event venues

Standing space at 5 ft² net per person gives a much higher load.

Office leases

Business areas at 150 ft² gross per person.

Retail stores

Mercantile sales floor at 60 ft² gross.

Gyms

Exercise rooms at 50 ft² gross.

Classrooms and training rooms

20 ft² net per student.

Posting a room's capacity

Assembly spaces must post their occupant load; get the starting number.

Planning exits

Occupant load drives exit count and width — start here, then read the code.

Comparing layouts

Chairs-only vs tables-and-chairs changes the load sharply.

Due diligence on a building

Rough capacity of each floor before talking to the building department.

Where the factors come from

The factors are Table 1004.5, 'Maximum Floor Area Allowances per Occupant', of the 2021 International Building Code, read on the ICC's public code site. Section 1004.5 says the occupant load 'shall be not less than that number determined by dividing the floor area under consideration by the occupant load factor assigned to the function of the space'. Factors are in square feet per occupant and are either gross (inside the exterior walls, including corridors, toilets and the like) or net (the occupied area only).

Each space's result is rounded up to a whole person. Section 1004.5.1 lets the building official approve a higher load, but never more than one occupant per 7 ft² of occupiable floor space; the page shows that ceiling for reference. Section 1004.8 sets concentrated business use at no less than one occupant per 50 ft² gross.

Limits: spaces with fixed seating (counted by seats, §1004.6) and covered mall buildings (§402.8.2) use other rules and aren't included. Your jurisdiction may use another code edition or amendments, and the building official decides the function of a space. Use this for planning, not for a permit. Everything runs in your browser.

Frequently asked questions

How do I calculate occupancy load?

Divide the floor area by the occupant load factor for its use from IBC Table 1004.5, and round up. 1,200 ft² of tables and chairs at 15 ft² net is 80 people.

What is the occupant load factor for a restaurant?

Dining with tables and chairs (unconcentrated assembly) is 15 ft² net per person; a commercial kitchen 200 ft² gross.

What's the difference between gross and net?

Gross includes everything inside the exterior walls; net counts only the occupied area, excluding corridors, toilets, closets and similar spaces.

What is the occupant load factor for an office?

Business areas: 150 ft² gross per occupant.

Can the occupant load be increased?

The building official may approve more, but not above one occupant per 7 ft² of occupiable floor space (IBC §1004.5.1).

Does my city use this table?

Most US jurisdictions adopt the IBC, sometimes with amendments or a different edition; check with your building department.